MI 3144 Euro Z 800V Featured

Other Instruments / adapters / accessories

The MI 3144 Euro Z 800 V is a multifunctional, portable battery (Li-ion) or mains powered test instrument with excellent IP protection: IP65 (case closed), IP54 (case opened). It can be controlled via an Android app A 1522 aMESM, MI 3152 EurotestXC, MI 3152H EurotestXC 2.5kV, MI 3155 EurotestXD or MI 3325 MultiServicerXD. The MI 3144 Euro Z 800 V is intended for measuring the effectiveness of automatic trip out protection in case of faults in transformers and other HV equipment. With its high precision line and loop impedance measurements on AC and DC circuits, high current dR 300A loop and line measurements for testing of partial currents and partial voltage drops, it is ideal for testing in industrial settings. It also supports contact voltage measurements, ELR electrical leakage relay testing with fault current injection, trip-out time measurement and DC source, line, battery and accumulator measurements.

Select a set

Videos

Instructional

Instructional

Standards applied

Building LV Installation

  • EISinsp Competences: Low Voltage Electrical Installation Safety Inspection
  • EISc Competences: Low Voltage Electrical Installation Safety for Contractors and Maintainers
  • IEC/EN 61557 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - series
  • IEC/EN 61557-3 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance

Earthing and lightning protection 

  • LPSinsp Competences: Lightning Protection of Buildings Inspection
  • LPSc Competences: Lightning Protection of Buildings for Contractors and Maintainers
  • IEC 62305 Protection against lightning - series

Electrical Energetics

  • EEA Competences: Electrical Energetic Installations with Automatic Trip-Out Ability
  • IEC/EN 60909-0 Short-circuit currents in three-phase a.c. systems - Part 0: Calculation of currents
  • IEC / EN 60947-2 Low-voltage switchgear and controlgear – Part 2: Circuit-breakers

Earthing and Grounding

  • EES Competences: Electrical Energetic Systems Earthing and Grounding Safety
  • HD 637 S1 Power installations exceeding 1 kV a.c.
  • IEEE Guide for Safety in AC Substation Grounding
  • IEEE 81-2012 IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Grounding System
  • IEEE 142 Recommended Practice for Grounding of Industrial and Commercial Power Systems
  • IEEE 367-2012 - IEEE Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power Fault
  • EN 50522 Earthing of power installations exceeding 1 000 V a.c.
  • RAT 2008 Spanish high-voltage regulation

Electrical switchboards safety

  • ESB Competences: Electrical Switchboards Safety Testing
  • IEC/EN 62271 High-voltage switchgear and controlgear - series
  • IEC/EN 62271-1 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
  • IEC/EN 62271-100 High-voltage switchgear and controlgear - Part 100: Alternating current circuit-breakers

Portable appliances safety

  • IEC/EN 60974 Arc welding equipment series
  • IEC/EN 60974-2 Arc welding equipment - Part 2: Liquid cooling systems

Properties

Measuring functions

  • High orecision 4-wire 300 A Z Line and Z Loop Impedance Tester;
  • High range impedance measurements in 800 V / 16 ... 420 Hz AC networks;
  • DC Source & Line Resistance measurements in 3 ... 260 V DC networks;
  • Hi Current dR 300 A 4-wire Partial Voltage drops and Current's Path Resistances;
  • Earth Leakage Relay (ELR) Trip-out Testing Time and Current;
  • ELR supported types AC, A, B;
  • Ground fault analysis with contact, touch and step voltage;
  • Floating voltmeter for partial contact results;
  • One-Clamp Hi current grounding method with clamps (Flex & Iron);
  • Selectable test load (16.6 % to 100 %);
  • Improved thermal performance;
  • Portable battery (Li-ion) or mains powered test instrument;
  • IP protection: IP65 (case closed), IP54 (case opened);
  • CAT IV 600 V (3000 m) safety category;
  • Bluetooth communication;
  • Black box design (remote-controlled via an Android device).

Technical data

  • Dimensions (w x h x d): 360 mm x 160 mm x 330 mm
  • Weight (without accessories): 6,5 kg

Applications

Power generation

  • Single flex clamp method for testing building construction integrity for lightning protection

Power distribution

  • Step and touch voltages of transformers
  • Ground integrity of conductive constructions with high current dR 300A
  • DC Networks’ and Power Sources’ Line and Loop Resistances

Industrial installations

  • Grid impedance and automatic trip-out ability
  • Impedance of live transformer and fault currents with hot factor
  • Partial voltage drops and partial clamp currents
  • Partial earth bonding resistance with single flex clamp method
  • Earth leakage relay and fault currents

Low voltage electrical installation safety

  • Substation electrical safety
  • Mains bonding and touch voltages during fault
  • Switchboards and automatic trip-out protection

Special locations 

  • DC installations

Hospital earthing and lightning protection 

  • Mains bonding and touch voltages during fault current

Specifications

Downloads

Datasheet Language Version Release Notes Type Size Download
MI 3144 Euro Z 800 V en 2022 14.09.2022 pdf 982.88 KB
Manual Language Version Release Notes Type Size Download
MI 3144 Euro Z 800V en 1.5.10 07.09.2022 20 752 881 pdf 2.45 MB Login
DoC Language Version Release Notes Type Size Download
UK Declaration of Conformity uk 02.09.2022 QR code External link Unknown
Android Language Version Release Notes Type Size Download
SW 1304 aMESM Android en 04.01.2021 QR code External link Unknown

Where to buy?

Search for distributors and partners

Have a question?

Speak with a specialist