MD 9055 TRMS Advanced Multimeter

Digital multimeters

The MD 9055 is another name for versatility in a small package. It supports a large number of measurements that make it a staple in both industrial and research environments. It has a 60000 counts display and supports a very wide array of measurements, including auto-hold of the measurement for working in confined spaces.

Select a set

Standards applied

Instrument safety towards user

  • EN 55032 Electromagnetic compatibility of multimedia equipment - Emission requirements
  • IEC 61000-2-12 Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
  • IEC/EN 61000-3-2 Electromagnetic compatibility (EMC) - Part 3-2 - Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
  • IEC/EN 61000-3-3 Electromagnetic compatibility (EMC) - Part 3-3 - Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
  • IEC/EN 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
  • IEC/EN 61000-4-3 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
  • IEC/EN 61000-4-4 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
  • IEC/EN 61000-4-5 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
  • IEC/EN 61000-4-7 Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto
  • IEC/EN 61000-4-8 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
  • IEC 61000-6-5:2015 Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for equipment used in power station and substation environment
  • The Low Voltage Directive LVD 73/23/EEC Electrical equipment designed for use within certain voltage limits
  • Directive EMC 89/336/EE on electromagnetic compatibility
  • IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use - series
  • IEC/EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
  • IEC/EN 61010-031 Amendment 1 - Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
  • IEC/EN 61010-2-032 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement
  • IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage

EMC safety

  • IEC/EN 61326 Electrical equipment for measurement, control and laboratory use - EMC requirements - series

Properties

Measuring functions

  • TRMS AC, DC voltage measurement;
  • TRMS AC, DC current measurement,
  • Capacitance measurement;
  • Resistance measurement;
  • Diode test,
  • Mains supply frequency measurement;
  • Frequency measurement of digital signals;
  • Continuity test (acoustic signalling);
  • Conductance measurement;
  • Temperature measurement;
  • 4-20 mA regulation loop test;
  • Non-contact electrical field detection.

Key features

  • TRMS: accurate readings on sinusoidal and non-sinusoidal signals.
  • Auto-ranging: user can switch between auto and manual ranging.
  • Temperature measurement: measures T1, T2 and T1 + T2 temperature in Celsius and in Fahrenheit.
  • Lead alert: incorrect lead connection alert.
  • dBm measurement results with settable reference value.
  • Auto-hold to freeze the measurement result for comfortable viewing.
  • Relative zero mode: relative function for comparing the difference between signals or removing background noise.
  • VFD: feature makes the instrument capable of measuring the true values in accordance with frequency.
  • MAX/MIN/AVG: recording of maximum, minimum and average values.
  • Crest (instantaneous peak) capture mode catches 5 ms long peaks.
  • Safety: CAT III / 1000 V overvoltage protection.
  • Backlight: large bright 4 digits 60.000 counts dual LCD display with backlight for working in dark conditions.

Technical data

  • Dimensions: 193 x 89 x 51 mm
  • Weight: 420 g

Applications

Preventative maintenance

  • Voltage measurements
  • Current measurements
  • Frequency measurements

Troubleshooting

  • Field service
  • Electronics
  • HVAC

General purpose

  • Industrial testing

Specifications

Downloads

Datasheet Language Version Release Notes Type Size Download
MD 9055 TRMS Advanced Multimeter en 2022 12.05.2022 pdf 374.76 KB {uk:Prenesi}
Manual Language Version Release Notes Type Size Download
MD 9055 TRMS Advanced Multimeter Multi-Language 1.1.11 22.12.2023 20753237 pdf 4.88 MB Login

Where to buy?

Search for distributors and partners

Have a question?