MD 9016 Electrical Field Service Multimeter

Digital multimeters

The digital multimeter MD 9016 is a perfect combination of size, Innovative functions and built-in PC communication. It is capable to detect and diagnose most electrical and electrotechnical problems. Display with large easy-to-read figures and one-handed operation make MD 9016 an extremely easy-to-use. This compact instrument combines a high level of functionality and small size and portability.

Select a set

Standards applied

Medical and surgery rooms' installations

  • IEC/EN 60364-7-710 Requirements for special installations or locations – Medical Location

Instrument safety towards user

  • EN 55032 Electromagnetic compatibility of multimedia equipment - Emission requirements
  • IEC 61000-2-12 Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
  • IEC/EN 61000-3-2 Electromagnetic compatibility (EMC) - Part 3-2 - Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
  • IEC/EN 61000-3-3 Electromagnetic compatibility (EMC) - Part 3-3 - Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
  • IEC/EN 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
  • IEC/EN 61000-4-3 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
  • IEC/EN 61000-4-4 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
  • IEC/EN 61000-4-5 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
  • IEC/EN 61000-4-7 Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto
  • IEC/EN 61000-4-8 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
  • IEC 61000-6-5:2015 Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for equipment used in power station and substation environment
  • The Low Voltage Directive LVD 73/23/EEC Electrical equipment designed for use within certain voltage limits
  • Directive EMC 89/336/EE on electromagnetic compatibility
  • IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use - series
  • IEC/EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
  • IEC/EN 61010-031 Amendment 1 - Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
  • IEC/EN 61010-2-032 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement
  • IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage

EMC safety

  • IEC/EN 61326 Electrical equipment for measurement, control and laboratory use - EMC requirements - series

Properties

Measuring functions

  • AC, DC voltage measurement;
  • AC, DC current measurement;
  • Capacitance measurement;
  • Resistance measurement;
  • Diode test;
  • Frequency measurement;
  • Continuity test (acoustic signaling);
  • Electric field detection;
  • Temperature measurement.

Key features

  • Auto-ranging: user can switch between auto and manual ranging.
  • EF detection: non-contact and probe contact electric field detection.
  • Relative zero mode: relative function for comparing the difference between signals or removing background noise.
  • Hold: data hold function freezes the display for later view.
  • PC Link: test results can be downloaded to the computer via the optional PC software.
  • Safe: CAT II / 1000 V, CAT III / 600 V and CAT IV / 300 V overvoltage protection.

Technical data

  • Dimensions (w x h x l): 80 x 50 x 161 mm
  • Mass (without accessories): 340 g

Applications

Preventative maintenance

  • Voltage measurements
  • Current measurements
  • Frequency measurements

Troubleshooting

  • Appliances troubleshooting
  • Field service
  • Electronics
  • HVAC

General purpose

  • Home maintenance
  • Hobby work

Specifications

Downloads

Datasheet Language Version Release Notes Type Size Download
MD 9016 Electrical Field Service Multimeter en 1.0 23.08.2018 pdf 773.66 KB {uk:Prenesi}
Manual Language Version Release Notes Type Size Download
MD 9016 Electrical Field Service Multimeter Multi-Language 2.1.5 17.11.2023 20 751 998 pdf 2.14 MB {uk:Zaklenjeno} Login
PC Software Language Version Release Notes Type Size Download
SW 1310 Data Recording Multi-Language 1.1.1 23.03.2021 zip 4.98 MB {uk:Zaklenjeno} Login
USB driver Language Version Release Notes Type Size Download
USB driver (DMM) en 1.1.1 23.03.2021 zip 13.62 MB {uk:Zaklenjeno} Login

Where to buy?

Search for distributors and partners

Have a question?

Speak with a specialist